TMS Europe LtdTMS Europe Ltd is a UKAS accredited calibration laboratory No.0461, as defined in our Schedule of Accreditation. As a UK manufacturer we're a member of Made in Britain.

Pico PT-104 Resistance Thermometer PC Data Logger

Pico PT-104 Resistance Thermometer PC Data Logger

TMS Stock Code:   PICOPT104

Providing the ultimate in resolution and accuracy the PT104 platinum resistance data logger is used to measure temperature (PT100/1000), voltage & resistance. Supplied with PicoLog data logging software capable of collecting 1 million samples.

Price:   £ 549.00 (£658.80 Including VAT at 20%)

Typical Availability:   3 - 8 days
Available for ordering online (UK+IE) or off-line.
[UKAS 0461 Logo]

Optional UKAS Calibration available

TMS Europe is a UKAS (ISO 17025) accredited calibration laboratory No. 0461. We offer this item with the option of a UKAS calibration certificate, at an additional cost, when ordered off-line. Please contact us with your requirements (calibration points, number of units) for a quote.

Description and Specifications
Description and Specifications

The PT-104 platinum resistance data logger gives you the ultimate in resolution and accuracy. You can use it to measure temperature, voltage and resistance. You can connect to it directly using either USB or via ethernet over a computer network, or you can connect to it remotely using a modem. When the accuracy of your temperature measurements is paramount the PT-104 is what you need.

  • Measures temperature, resistance and voltage
  • High resolution and accuracy
  • No power supply required
  • USB and Ethernet (RJ45) interface
  • For use with PT100 and PT1000 sensors

Accuracy and Resolution
Although accurate temperature sensors are widely available, it has been difficult to take advantage of them due to errors caused by the measuring device. The PT104 however, is inherently accurate due to its novel design. Rather than relying on voltage references (which tend to be temperature sensitive) it uses 'reference' resistors which are extremely stable (low temperature co-efficient and drift). The exact value of each resistor is stored in an EEPROM to provide the ultimate in accuracy (yearly re-calibration is recommended). To achieve the 0.001 °C resolution a highly-advanced ADC is used that can resolve to better than 1 part in 16 million.

Temperature
The PT104 measures temperature using platinum resistance thermometers (PRTs). Both common industry standards (PT100 and PT1000) are supported. The unit is compatible with 2, 3 and 4 wire sensors (4 wire PT100 sensors are recommended for more accurate measurements, especially on longer lead lengths). We offer a wide range of PT-100 temperature sensors which are available for use with the PT-104.

Resistance
When measuring resistance, the unit uses a four-wire circuit to give the greatest possible accuracy.
Two resistance ranges are available (0 to 375 ohms and 0 to 10,000 ohms). The unit is calibrated for 0 to 375 ohms so this range should be used for accurate measurements.

Voltage
For voltage measurements, each input connector can be treated as a differential input with ground, or two single-ended inputs. Both inputs must be zero volts or above, though it does not matter which input has the higher voltage.
Two voltage ranges are available (0 to 115 mV and 0 to 2500 mV). For the most accurate measurements use the 0 to 2500 mV range.

Software
The PT-104 is supplied with PicoLog data logging software which can collect up to 1 million samples. PicoLog will automatically detect which sensor is connected and will display readings in the correct units. Also supplied is a software development kit. The SDK contains a range of software drivers and example code that you can use to write your own software or to use your PT-104 data logger with third party software. Features include:
  • Multiple views - view data as a graph, spreadsheet or text
  • Parameter scaling - convert raw data into standard engineering units
  • Math functions - use mathematical equations to calculate additional parameters
  • Alarm limits - program an alert if a parameter goes out of a specified range
  • IP networking - transfer measurements via a LAN or over the Internet
  • Full details on PicoLog
  • Software development kit includes drivers and example code for various programming languages including C, Excel and LabVIEW.


UKAS calibration is optionally available at extra cost, either of the unit on its own or with RTDs as a system. Please contact us for more details.

InputTemperatureResistanceVoltage
Range-200 to 800°C0 to 375 Ω, 0 to 10 kΩ0 to 115 mV, 0 to 2.5 V
Accuracy0.01°C20 ppm0.2% (2.5 V)
Temperature coefficient5 ppm/°C5 ppm/°C100 ppm/°C
RMS noise with filter0.01°C10 ppm10 ppm
Resolution0.001°C1 µΩ0.156 µV

Input Sensors: PT100, PT1000; 2, 3 & 4-wire
Overload protection: ±30 V
Converter resolution: 24 bits
Conversion time: 720 ms per channel
Input Connector: 4x 4-pin mini DIN
Output connectors: USB and Ethernet (RJ45)
Power requirements: Powered from USB port or Ethernet (requires PoE support)
Manufacturer's Warranty: 5 years

Required Computer Operating System: 32 or 64-bit version of Microsoft Windows XP SP2 (or above), Vista or 7
Required Computer Memory: 256 MB (XP) / 1 GB (Vista / 7)
Required Computer Ports: USB 2.0 compliant port, USB 1.1 or Ethernet (RJ45)

Operating Temperature Range: 0 °C to 70 °C
Operating Humidity Range: 20% to 90% RH, non-condensing
Dimensions: 184 x 135 x 36 mm (approx 5.31 x 7.24 x 1.42 in)
Weight: 350 g (approx 12.3 oz)

Your Recently Viewed Items :