Type N Mineral Insulated (MI) Inconel sheathed thermocouples in 3mm diameter with 1mtr twin-twisted PFA leads. These thermocouples are available in various lengths and are suitable for temperatures up to 1220°C. These thermocouples are produced from batch calibrated cable and conform to AMS 2750.
These exceptional value thermocouples may be subject availablity. If ordering multiple thermocouples, multiple calibration certifcates maybe given (depending on stock availability), a minimum 4 thermocouples of the same length will be covered by one certificate.
These thermocouples are AMS 2750 and Nadcap compliant and suitable for Secondary Standard, Temperature Uniformity Surveys, System Accuracy Tests (3.1.6), Control Recording and Monitoring and Load . Each thermocouple has a unique label attached, giving full traceability to a UKAS Calibration Certificate, which gives the calibration results of the two samples for each end of the roll used to make the thermocouples.
Temperature Ranges: 0°C to 1200°C (0 - 1100°C for continuous use)
Batch Calibration Points: 400-1200°C Every 100°C
One Calibration Certificate is supplied with every order.
Note: These temperatures apply to the MI sheath, the pot seal temperature and tails should not exceed 135°C.